Model no | UE-FPS-04 | |
---|---|---|
Mains input | 230V, ±10%, 50Hz, Single phase | |
Type | CV/CC | |
Output | Voltage | 24V DC, ± 1V adjustable by potentiometer mounted on front panel with lock nut |
Current | 20A Max adjustable by potentiometer mounted on front panel with lock nut | |
Line Regulation | Better than 0.1% for a line change of 207V to 253V | |
Load Regulation | Better than 0.1% from no load to full load and vice versa | |
Ripple | Less than 3mV (RMS) or 100mV peak to peak | |
Protections | a) Unit is protected by input fuse b) Unit is protected against input surges c) Output is protected against over loads & Continuous short circuits |
|
Indication(s) | a) One LED for input b) One LED each for CV and CC indication c) One 3½ digit digital panel meter is provided to read output voltage d) One 3½ digit digital panel meter is provided to read output current |
|
Controls | a) One ON/OFF switch to ON/OFF the Unit. b) One Coarse potentiometer to Control the output voltage & current. | |
Mechanical | Bench top / 19" Rack Mounting as required by you | |
Cooling | Forced air cooling | |
Operating Environment | 0°C to +50°C | |
Terminals | Separate piri Terminal Block on Front Panel for Input(AC) and Output(DC) and for Remote sensing |