Model no | UE-MPS-96 | |
---|---|---|
Mains input | 220V, ±10%, 50-6Hz, Single phase | |
Type | CV/CC | |
Output | a)+/-5V/5A b)+/-15V/5A c)0-30V/0-5A |
|
Line Regulation | ± 0.1% max. Output Voltage for ± 10% change in mains Input Voltage. | |
Load Regulation | ± 0.1% max. Output Voltage Change for No-load to full load or Vice-versa. | |
Ripple | Less than 1mV R.M.S | |
Protections | a) Unit is protected by input fuse b) Unit is protected against input surges c) Output is protected against over loads & Continuous short circuits. |
|
Indication(s) | a) One LED for input b) One LED each for CV and CC indication c) One 3½ digit digital panel meter is provided to read output voltage d) One 3½ digit digital panel meter is provided to read output current |
|
Controls | a) One ON/OFF switch to ON/OFF the Unit b) One Coarse and one fine potentiometer to Control the output voltage c) One Coarse and one fine potentiometer to Control the output current d) NOTE : d) One potentiometer with locknut is Provided for over voltage setting if required. |
|
Mechanical | Bench top / 19" Rack Mounting as required by you. | |
Cooling | Forced air cooling | |
Operating Environment | 0°C to +50°C | |
Terminals | Banana socket(s) at front panel & Piri Terminal Strip with remote sensing at rear panel if Required. |